New Product!!!

Procon 2 - Monitor 2 Engines with One Procon

   

The New Standard in Protocol Conversion.

 

PROCON Protocol converter converts either J1587/J1708 or J1939 protocol to Modbus RTU, DF1, ASCII, or for use by a PLC (Programmable Logic Controller). Call us if customized output or other protocols are needed to fit your specific requirements.

 
   

Features of the PROCON 2:

Supports two engines operating from one Procon box. The engines must have different source addresses (J1939) or different MID's (J1587/J1708). Information for each engine can then be obtained by using that engine's slave address.

Each data line is protected against ESD as well as large DC voltages.

Communications options now include 9.6 or 19.2 kbaud and 1 or 2 stop bits.

During Modbus messages, engine bus messages will still be accepted. This prevents some engines from timing out if the Modbus poll rate is high.

Two additional diagnostic LED's are provided to show whether Modbus requests are received and whether a reply is sent.

The Procon 2 Protocol Converter converts either J1587/J1708 or J1939 protocol to Modbus RTU, DF1, ASCII, or for use by a PLC (Programmable Logic Controller).
Click Here To View Dimensional Information.

   

Operates on:

~ 12 to 24 VDC, reverse polarity protected,
low power consumption (750 mW)

~ Outputs RS485 or RS232

No end user configuration necessary.

Procon 2 Protocol Converter

 

Example Configurations:

J1939 Protocol with RS232 output.
J1708 Protocol with RS232 output.
J1939 Protocol with RS485 output.
J1708 Protocol with RS485 output.
Example configuration lable for J1939 Protocol with RS232 output Example configuration lable for J1708 Protocol with RS232 output Example configuration lable for J1939 Protocol with RS485 output Example configuration lable for J1708 Protocol with RS485 output

Part No.

PC1939MBRS2
(MODBUS)
PC1708MBRS2
(MODBUS)
PC1939MBRS4
(MODBUS)
PC1708MBRS4
(MODBUS)
For other protocols please call (780) 963-8930 or Email: sales@c-a-i.net

Specifications for Procon:

Click Here to view a list of specifications and interface information.

 

Additional Features:  

~ We can easily adapt to meet other requirements.

~ No additional configuration software required.

~ No need to understand J1587/J1708 or J1939 protocols.

~ Simply program your PLC with our appropriate registers.

~ Memory map contains over 45 parameters to cover most requirements.

 

To Download either Memory Map, click below:

J1708
J1939
Adobe 6.0 PDF File (Opens in Browser Window. To download as file, right-click and select "Save Target As") Adobe 6.0 PDF File (Opens in Browser Window. To download as file, right-click and select "Save Target As")

Procon 2 Protocol Converter

 

C A Instruments Ltd. is willing to customize the output to fit specific customer requirements.

For further inquiries Email or Phone (780) 963-8930.