Beede Electrical Instruments and Gauges - Specifications

Back To Beede Electrical Instruments Product List

Environmental Specifications:

Accuracy
Tachometers: ±2% of F.S. @ 75°F (24°C)
Hourmeteres: ±1% @ 75°F (24°C)
Speedometers: ±2% of F.S. (Analog) @ 75°F(24°C)
(Odometeres) ±1% Distance Indication
Gauges: Vary with application type.

 

 

 

 

 

Temperature
Operating: -20°F to +185°F (-30°C to 70°C)
Maximum Change: ±2% F.S. from 75°F (24°C) indication

 

 

 

Shock
50G, 9-13 ms half sine, 25 shocks in each of three orthogonal axes with now damage

 

 

 

Vibration
0.060" double amplitude 10-80 Hz. Two hours in each of three orthogonal axes: remains within initial accuracy

 

 

 

Salt Spray
Meets or exceeds ASTM 117, 48 hours

 

 

Operating Voltage
12-16 VDC standard; for 24 VDC operation, contact us

 

 

Over Voltage
Withstands 18 V continuously for one hour

 

 

Load Dump
Meets SAE J1113, 3 positive 80V transients, one minute intervals

 

 

Dimensions:

Dimensions for Beede Gauges, Speedometers, Tachometers and Electrical Instruments

 

 

Reverse Polarity Protection
Standard, all instruments
 

 

Voltage Variance
±1% of initial reading, 12-16 VDC

 

If you require any more info, please email us.